Allows a single physical UniOP terminal to talk to two separate PLC systems running different protocols concurrently. Clarifying the Download Architecture
Put the physical UniOP HMI into (usually achieved by holding down any three keys during panel power-up, or following the on-screen prompts).
: Extended functions for alarm handling, trend buffers, recipe data, and report printing. 3. Compatibility & System Requirements
"I need the project file," Elias muttered, scouring the old server. He found the backup, but his modern workstation didn't recognize the extension. He needed UniOP Designer 6 Uniop Designer 6 Software Download
| Problem | Possible Causes | Solution | |---------|----------------|----------| | Cannot connect PC to panel | Cable not connected, wrong COM port, panel not in Configuration Mode | Verify cable (CA2/CA114). Check COM port settings in Designer. Ensure panel is powered and in Configuration Mode (see below for forced entry) | | Download fails or times out | Corrupted project, incompatible firmware version, or EMI interference | Recompile project. Use the lowest baud rate (9600). Try UniDataExchanger instead of Designer | | Panel does not enter Configuration Mode | Startup corruption or keys not held long enough | For keyed models: switch off, press and hold any 3 keys, then turn on while still holding keys until “Configuration Mode” appears. For keyless touch models: switch off, touch left side of screen, switch on, then tap right side of screen once per second | | Communication error codes (COM ERR 04, 05, 09) | PLC in STOP mode, disconnected cable, incorrect data area, duplicate node numbers | Check PLC status. Verify cable continuity. Confirm data area addresses. Ensure no duplicate Profibus DP node numbers | | Designer cannot upload from old panel (e.g., EK‑12, EK‑16N) | Firmware version mismatch or unsupported panel | Use UniDataExchanger. If that fails, try an older Designer version (5.x). Search community forums for specific panel models | | Mouse cursor does not appear in Designer | Mouse driver not loaded or conflict | Exit Designer. Verify mouse driver is installed (check CONFIG.SYS / AUTOEXEC.BAT). Reconnect mouse and restart |
For engineers tasked with maintaining legacy industrial equipment, remains an essential utility. While not available through casual download links, it is accessible through official EXOR support channels. Ensuring you have a backed-up copy of the installer and the necessary hardware keys is vital for the lifecycle management of any facility running UniOp HMI panels.
: Official service packs (such as version 6.10.02.03 ) can be downloaded from the Exor Support Portal , but they require a previous full installation of Designer 6.01 or later to function. Allows a single physical UniOP terminal to talk
Supports over 200 communication protocols including Modbus, Profibus, Allen-Bradley DF1, Siemens MPI, and Omron Host Link.
Note: You may be required to register a free account or provide a corporate email to access legacy software archives. 2. Authorized Industrial Automation Distributors
When searching online for an you must understand how EXOR packages this legacy platform. Designer Software Updates | EXOR Int. S.p.A. He needed UniOP Designer 6 | Problem |
Yes, but only after installing the latest Service Pack (6.2.x). Some users report display scaling issues – fix by right-clicking the .exe → Properties → Compatibility → Change high DPI settings.
As legacy software, Designer 6 is optimized for older Windows environments but can be adapted for modern systems.